Our flat panel detectors are designed to meet a broad spectrum of imaging applications in the industrial and security industries. Varex flat panel detectors prevent geometric distortion and minimize effects of magnetic field and radiation. The technology found in our detectors allows our customers to take full advantage of superior digital image quality along with high throughput, as well as CT capabilities. These detectors present a uniform, undistorted, high-resolution image throughout the field of view, enabling technicians to take images of the internal structures of objects such as electronic circuits and mechanical parts.

Products
Varex ProductPanel SizePixel MatrixPixel Size µmEnergy Range (kV)Scintillator Type
2530HE25 x 30 cm1792 x 2176
896 x 1088
13920 kV - 16 MV DRZ+
1515DXT-I15 x 15 cm1152 x 1152
576 x 576
12740 - 225 kVp Direct Deposit CsI, DRZ+
2520DX-I25 x 20 cm1,536 x 1,920
768 x 960
12740 - 225 kVp Direct Deposit CsI, DRZ+
1308DX13 x 8 cm1024 x 640
512 x 320
12740 - 160 kVpDRZ+, CsI
1313DX 更多资源13 x 13 cm1024 x 1024
512 x 512
12740 - 160 kVpDRZ+, CsI
1313DXT13 x 13 cm1024 x 1024
512 x 512
12740 - 160 kVpDRZ+, CsI
1508 DXT15 x 8 cm1152 x 630
576 x 320
12740 - 160 kVpDRZ+, CsI
2530C25 x 30 cm1792 x 217613940 - 160 kVp DRZ+
2530DX25 x 30 cm1792 x 2176
896 x 1088
13940 - 160 kVp DRZ+, CsI
1308DXT13 x 8 cm1024 x 640
512 x 320
12740 - 160 kVp CsI, DRZ+, DRZ Standard
3030DX-I30 x 30 cm1,536 x 1,536
1,516 x 1,516
19440 - 225 kVpDRZ+, Integral Columnar CsI: TI
1207 NDT12 x 7 cm1536 × 86474.8 12 - 160 kVGadox or CsI:Tl
1512NDT15 x 12 cm1944 × 153674.8 12 - 160 kVGadox or CsI:Tl
2315NDT23 x 15 cm3072 × 194474.812 - 225 kV Gadox or CsI:Tl
XRD 0822 xO/xP20 x 20 cm1024 × 1024 200 20 kV – 15 MVGadox or CsI:Tl
XRD 1611 xP41 x 41 cm4096 × 409610040 kV – 15 MV (XRD 1611 AP)
20 kV – 15 MV (XRD 1611 CP)
Direct deposit CsI or Gadox
XRD 1620 xN CS41 x 41 cm2048 × 204820040 kV – 15 MV (XRD 1620 AN CS)
20 kV – 15 MV (XRD 1620 CN CS)
Direct deposit CsI or Gadox
XRD 1621 xN ES41 x 41 cm2048 × 204820040 kV – 15 MV (XRD 1621 AN ES)
20 kV – 15 MV (XRD 1621 CN ES)
Direct deposit CsI or Gadox
XRD 1622 AO, AP41 x 41 cm2048 × 204820020 kV – 15 MVDirect deposit CsI or Gadox
XRD 1642 AP41 x 41 cm1024 × 102440020 keV – 15 MVDirect deposit CsI or Gadox
XRpad 4343 F43 x 43 cm4318 × 4320100 20 - 150 kVDirect deposit CsI or Gadox
4343HE 更多资源42.7 x 42.7 cm3,072 x 3,07213930 kV - 16MVDRZ+
XRD 4343CT43 x 43 cm2880 × 2880 150Direct deposition CsI:Tl and Gadox
XRpad2 434343 x 43 cm4288 x 428810020 - 150 kVDirect Depost CsI:TI, Gadox
XRD 3025 更多资源30 x 253008 x 251210020 - 225 kV (G-22)
20 - 450 kV (G-45)
Gadox or CsI:Tl
XRpad2 302530 x 25 cm3004 x 250810020 - 150 kVDirect Deposit CsI, Gadox
XRpad2 433643 x 35 cm4288 × 3524 10020 - 150 kVDirect Deposit CsI, Gadox
1616DXT16 x 16 cm1280 x 1280
640 x 640
12740 - 150DRZ+, CsI
4343DX-I42.7 x 42.7 cm 3,072 x 3,07213940 kV - 320 kV DRZ, CsI:TI
3030DXV-I30 x 30 cm1536 x 1536
1516 x 1516
19440 - 125 kVpDRZ+, CsI
3020DXV-I30 x 20 cm1536 x 1024
1516 x 1004
19440 x 225 kVpDRZ+, CsI

System manufacturers are responsible for qualifying and validating their products for their intended uses and meeting all applicable requirements.

Product Inquiry: Security & Industrial Flat Panel Detectors

If you have a flat panel service request, proceed to the Flat Panel service report form and provide the requested information.

If you have a tube warranty/product return, please fill out the X-Ray Tubes Housing & Warranty form.

This report is to be submitted on each Flat Panel removed from service. Each flat panel must be returned with a completed Service Report describing the reason for return, operating conditions with install and remove dates in order to receive warranty consideration.

Before an RMA # can be issued on “Out Of Warranty Returns” a PO for $1,000.00 needs to be supplied at time an RMA# is requested. Note: All products must be cleaned of blood, contrast media or body fluids before returning.

Please fill out this form completely and hit submit. We will then email you further instructions along with an RMA number. Please do not ship any material to us without an RMA number; we will not be able to accept it.

Please Return within 90 days of RMA# Issued. After 90 days, RMA# will be closed and you will need to request a new RMA# to return your product.

Once you have received your RMA, please ship material to:

VAREX IMAGING CORPORATION
1678 Pioneer Road
Salt Lake City, UT 84104-4298
Receiving Door #15

PLEASE SHOW THE RMA# ON THE OUTSIDE OF ALL PACKAGING

All fields with an * are required


Contact Information


Product Information


Defect Information

Fill out information below as completely as possible.

How long has the system been operating before you see the defect?

Please describe the system set-up at the time of the failure:

Settings

kV

mAs