Our flat panel detectors are designed to meet a broad spectrum of imaging applications in the industrial and security industries. Varex flat panel detectors prevent geometric distortion and minimize effects of magnetic field and radiation. The technology found in our detectors allows our customers to take full advantage of superior digital image quality along with high throughput, as well as CT capabilities. These detectors present a uniform, undistorted, high-resolution image throughout the field of view, enabling technicians to take images of the internal structures of objects such as electronic circuits and mechanical parts.

Products

Displaying results for Nondestructive Testing Detectors

Product Panel Size Pixel Matrix Pixel Size µm Energy Range (kV) Scintillator Type
2530HE
25 x 30 cm

1792 x 2176
896 x 1088

139
20 kV - 16 MV DRZ+
1515DXT-I
15 x 15 cm

1152 x 1152
576 x 576

127
40 - 225 kVp Direct Deposit CsI, DRZ+
2520DX-I
25 x 20 cm

1,536 x 1,920
768 x 960

127
40 - 225 kVp Direct Deposit CsI, DRZ+
1308DX
13 x 8 cm

1024 x 640
512 x 320

127
40 - 160 kVp DRZ+, CsI
1313DX
13 x 13 cm
1024 x 1024
512 x 512
127
40 - 160 kVp DRZ+, CsI
1313DXT
13 x 13 cm

1024 x 1024
512 x 512

127
40 - 160 kVp DRZ+, CsI
1508 DXT
15 x 8 cm
1152 x 630
576 x 320
127
40 - 160 kVp DRZ+, CsI
1515DXT
15 x 15 cm

1152 x 1152
576 x 576

127
40 - 160 kVp DRZ+, CsI
2520DX
25 x 20 cm

1536 x 1920
768 x 960

127
40 - 160 kVp DRZ+, CsI
2530C
25 x 30 cm

1792 x 2176

139
40 - 160 kVp DRZ+
2530DX
25 x 30 cm

1792 x 2176
896 x 1088

139
40 - 160 kVp DRZ+, CsI
1308DXT
13 x 8 cm

1024 x 640
512 x 320

127
40 - 160 kVp CsI, DRZ+, DRZ Standard
3030DX-I
30 x 30 cm

1,536 x 1,536
1,516 x 1,516

194
40 - 225 kVp DRZ+, Integral Columnar CsI: TI
1207N
12 x 7 cm

1536 × 864

74.8
12 - 160 kV Gadox or CsI:Tl
1512N
15 x 12 cm

1944 × 1536

74.8
12 - 225 kV Gadox or CsI:Tl
2315N
23 x 15 cm

3072 × 1944

74.8
12 - 160 kV Gadox or CsI:Tl
XRD 0822 xO/xP
20 x 20 cm

1024 × 1024

200
20 kV – 15 MV Gadox or CsI:Tl
XRD 1611 xP
41 x 41 cm

4096 × 4096

100
40 kV – 15 MV (XRD 1611 AP)
20 kV – 15 MV (XRD 1611 CP)
Direct deposit CsI or Gadox
XRD 1620 xN CS
41 x 41 cm

2048 × 2048

200
40 kV – 15 MV (XRD 1620 AN CS)
20 kV – 15 MV (XRD 1620 CN CS)
Direct deposit CsI or Gadox
XRD 1621 xN ES
41 x 41 cm

2048 × 2048

200
40 kV – 15 MV (XRD 1621 AN ES)
20 kV – 15 MV (XRD 1621 CN ES)
Direct deposit CsI or Gadox
XRD 1622 AO, AP
41 x 41 cm

2048 × 2048

200
20 kV – 15 MV Direct deposit CsI or Gadox
XRD 1642 AP
41 x 41 cm

1024 × 1024

400
20 keV – 15 MV Direct deposit CsI or Gadox
XRpad 4343 F
43 x 43 cm

4318 × 4320

100
20 - 150 kV Direct deposit CsI or Gadox
4343HE
42.7 x 42.7 cm

3,072 x 3,072

139
30 kV - 16MV DRZ+
XRD 4343CT
43 x 43 cm

2880 × 2880

150
20 - 225 kV Direct deposition CsI:Tl and Gadox
XRpad2 4343
43 x 43 cm

4288 x 4288

100
20 - 150 kV Direct Depost CsI:TI, Gadox
XRD 3025
30 x 25

3008 x 2512

100
20 - 225 kV (G-22)
20 - 450 kV (G-45)
Gadox or CsI:Tl
XRpad2 3025i
30 x 25 cm

3008 x 2512

100
20 - 150 kV Direct Deposit CsI, Gadox
XRpad2 4336i
43 x 35 cm

4288 × 3524

100
20 - 150 kV Direct Deposit CsI, Gadox
1616DXT
16 x 16 cm

1280 x 1280
640 x 640

127
40 - 150 DRZ+, CsI
3030DXV-I
30 x 30 cm

1536 x 1536
1516 x 1516

194
40 - 125 kVp DRZ+, CsI
3020DXV-I
30 x 20 cm

1536 x 1024
1516 x 1004

194
40 - 225 kVp DRZ+, CsI
2307N
23 x 7 cm

3072 x 864

74.8
12 - 225 CsI:TI
2307S
23 x 7 cm

3072 x 864

74.8
12 - 90 Gadox

System manufacturers are responsible for qualifying and validating their products for their intended uses and meeting all applicable requirements.

Product Inquiry: Security & Industrial Flat Panel Detectors

If you have a flat panel service request, proceed to the Flat Panel service report form and provide the requested information.

If you have a tube warranty/product return, please fill out the X-Ray Tubes Housing & Warranty form.

This report is to be submitted on each Flat Panel removed from service. Each flat panel must be returned with a completed Service Report describing the reason for return, operating conditions with install and remove dates in order to receive warranty consideration.

Before an RMA # can be issued on “Out Of Warranty Returns” a PO for $1,000.00 needs to be supplied at time an RMA# is requested. Note: All products must be cleaned of blood, contrast media or body fluids before returning.

Please fill out this form completely and hit submit. We will then email you further instructions along with an RMA number. Please do not ship any material to us without an RMA number; we will not be able to accept it.

Please Return within 90 days of RMA# Issued. After 90 days, RMA# will be closed and you will need to request a new RMA# to return your product.

Once you have received your RMA, please ship material to:

VAREX IMAGING CORPORATION
1678 Pioneer Road
Salt Lake City, UT 84104-4298
Receiving Door #15

PLEASE SHOW THE RMA# ON THE OUTSIDE OF ALL PACKAGING

All fields with an * are required


Contact Information


Product Information


Defect Information

Fill out information below as completely as possible.

How long has the system been operating before you see the defect?

Please describe the system set-up at the time of the failure:

Settings

kV

mAs