Varex Imaging (as Varian Medical Systems) was the first company in the world to deliver amorphous silicon flat-panel detectors capable of both fluoroscopic and radiographic digital imaging. Varex’s X-ray flat panel detectors for digital radiography work by converting the X-rays that strike its surface into light, and then turning the light into electronic data that a computer can display as a high-quality digital image.

Our flat panel detectors combine the best in amorphous silicon sensor panels, radiation-converting materials, low-noise analog and high-speed digital electronics, custom ASIC control and processing electronics, and compact packaging.

Varex also offers CMOS flat panel X-ray detectors. These detectors employ an innovative CMOS sensor design to provide a new level of performance and reliability for X-ray systems used in mammography, fluoroscopy, cone beam CT, and projection radiography markets in medical and dental. Its major advantages are high frame rates, low noise, high reliability, no image lag, and high spatial resolution. Clinical benefits in medical applications include lower radiation dose to the patient without compromising image quality. CMOS Detectors are more flexible, more stable, more sensitive, and faster than TFT-based flat panel detectors while producing higher resolution images.

Products

Displaying results for Digital Radiography Detectors

Product Technology Panel Size Pixel Matrix Pixel Size µm Energy Range (kV) Scintillator Type
2530W Radiographic
25 x 30 cm

1792 x 2176

139
DRZ+, CsI
4336R Radiographic
43 x 36 cm

3072 x 2560
3052 x 2540

139
DRZ+, CsI
4336W Radiographic
43 x 36 cm

3072 x 2560
3052 x 2540

139
DRZ+, CsI
4336X Radiographic
43 x 36 cm

3072 x 2560
3052 x 2540

139
DRZ+, CsI
4343R ver3 Radiographic
43 x 43 cm

3072 x 3072
3052 x 3052

139
DRZ+, CsI
2020X Dynamic
20 x 20 cm

1024 x 1024
512 x 512

194
CsI
2020DXV Dynamic
20 x 20 cm

1024 x 1024
512 x 512

194
Csl
2121DXV Dynamic
21 x 21 cm

1024 x 1024
512 x 512

205
Csl
1207 CMOS Dynamic
12 x 7 cm

1536 × 864

74.8
High Resolution Csl or Gadox
1512 CMOS Dynamic
15 x 12 cm

1944 × 1536

74.8
High Efficiency CsI, High Resolution CsI, or High Resolution Gadox
XRpad 4343 F Radiographic
43 x 43 cm

4318 × 4320

100
Direct deposit CsI
XRpad2 3025 HWC Radiographic
30 x 25 cm

3004 x 2508

100
20 - 150 kV Direct deposit CsI
XRpad2 4336 HWC Radiographic
43 × 35 cm

4288 × 3524

100
20 - 150 kV Direct deposit CsI
XRD 4343 RF Radiographic
43 x 43 cm

2880 × 2880

150
Direct deposit CsI
4343DXV Amorphous Silicon
43 x 43 cm

3,072 (h) x 3,072 (v)
3,032 (h) x 3,032 (v)

139
Integral columnar CsI:Tl
2121XV Dynamic
21 x 21 cm

1024 x 1024

205
CsI
4343 RC Radiographic
43 x 43 cm

3072 x 3072
3052 x 3052

139
DRZ+, CsI
XRpad2 4343 HWC Radiographic
43 x 43

4288 x 4288

100
Direct deposit CsI
4343W Radiographic
43 x 43 cm
3072 x 3072
139
DRZ+, Standard CsI, Premium CsI

System manufacturers are responsible for qualifying and validating their products for their intended uses and meeting all applicable requirements.

Product Inquiry: Medical Flat Panel Detectors

If you have a flat panel service request, proceed to the Flat Panel service report form and provide the requested information.

If you have a tube warranty/product return, please fill out the X-Ray Tubes Housing & Warranty form.

This report is to be submitted on each Flat Panel removed from service. Each flat panel must be returned with a completed Service Report describing the reason for return, operating conditions with install and remove dates in order to receive warranty consideration.

Before an RMA # can be issued on “Out Of Warranty Returns” a PO for $1,000.00 needs to be supplied at time an RMA# is requested. Note: All products must be cleaned of blood, contrast media or body fluids before returning.

Please fill out this form completely and hit submit. We will then email you further instructions along with an RMA number. Please do not ship any material to us without an RMA number; we will not be able to accept it.

Please Return within 90 days of RMA# Issued. After 90 days, RMA# will be closed and you will need to request a new RMA# to return your product.

Once you have received your RMA, please ship material to:

VAREX IMAGING CORPORATION
1678 Pioneer Road
Salt Lake City, UT 84104-4298
Receiving Door #15

PLEASE SHOW THE RMA# ON THE OUTSIDE OF ALL PACKAGING

All fields with an * are required


Contact Information


Product Information


Defect Information

Fill out information below as completely as possible.

How long has the system been operating before you see the defect?

Please describe the system set-up at the time of the failure:

Settings

kV

mAs